Thermocouple Wire Insulation

  Configure your Thermocouple RTD Cable

 Thermocouple Wire Insulation

Continuous and short term operating rage of different Thermocouple Insulation
Insulation Layers Maximum Temperature Range Maximum Temperature Range Resistance Against Chemical
(Continuous ) in °C (Short Time ) in °C
Mica Tape/ Fiber Braided 600 700 Good
Fiber Braided/ Fiber Braided 400 500 Good
Fiber Braided/ Fiber Braided/ SS 410 520 Very Good
Cotton Braided/ Cotton Braided 110 100 Poor
PVC/ PVC 110 200 Fair
PTFE Wrap/ Kapton Wrap 300 350 Very Good
Kapton Wrap (Twisted Pair) 320 420 Very Good
FEP (Twisted Pair) 204 260 Very Good
PTFE (Twisted Pair) 350 400 Very Good
Silicon Rubber/ Silicon Rubber 250 300 Good
PTFE Wrap/ Silicon Rubber 300 350 Good
PTFE/ Fiber Braided/ SS 480 540 Very Good
PVC Twisted Pair/ Al Mylar/ PVC Jacket Overall 105 120 Good